Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Vu, TheDang; Shishido, Hiroaki*; Aizawa, Kazuya; Kojima, Kenji M*; Koyama, Tomio*; Oikawa, Kenichi; Harada, Masahide; Oku, Takayuki; Soyama, Kazuhiko; Miyajima, Shigeyuki*; et al.
Nuclear Instruments and Methods in Physics Research A, 1006, p.165411_1 - 165411_8, 2021/08
Times Cited Count:1 Percentile:18.12(Instruments & Instrumentation)Vu, TheDang; Shishido, Hiroaki*; Kojima, Kenji M*; Koyama, Tomio*; Oikawa, Kenichi; Harada, Masahide; Miyajima, Shigeyuki*; Oku, Takayuki; Soyama, Kazuhiko; Aizawa, Kazuya; et al.
Superconductor Science and Technology, 34(1), p.015010_1 - 015010_10, 2021/01
Times Cited Count:3 Percentile:26.56(Physics, Applied)Vu, TheDang; Nishimura, Kazuma*; Shishido, Hiroaki*; Harada, Masahide; Oikawa, Kenichi; Miyajima, Shigeyuki*; Hidaka, Mutsuo*; Oku, Takayuki; Soyama, Kazuhiko; Aizawa, Kazuya; et al.
Journal of Physics; Conference Series, 1590, p.012036_1 - 012036_9, 2020/07
Times Cited Count:0 Percentile:0.01(Engineering, Electrical & Electronic)Miyajima, Shigeyuki*; Shishido, Hiroaki*; Narukami, Yoshito*; Yoshioka, Naohito*; Fujimaki, Akira*; Hidaka, Mutsuo*; Oikawa, Kenichi; Harada, Masahide; Oku, Takayuki; Arai, Masatoshi*; et al.
Nuclear Instruments and Methods in Physics Research A, 842, p.71 - 75, 2017/01
Times Cited Count:13 Percentile:77.73(Instruments & Instrumentation)Nakamura, Tatsuya; Katagiri, Masaki; Chen, Y. E.*; Ukibe, Masahiro*; Okubo, Masataka*
Nuclear Instruments and Methods in Physics Research A, 559(2), p.766 - 768, 2006/04
Times Cited Count:13 Percentile:65.77(Instruments & Instrumentation)We have been developing a position-sensitive neutron detector, which exhibits a high spatial resolution of the order of 10 microns and high detection efficiency. The analysis on the pulse-heights or on the time-delay between the STJs gives incident positions of the neutrons. In this paper, the response of the STJs/LBO neutron detector measured using a cold neutron beam is presented. The two STJs have the same size of 50 50 m and their distance is 1.3 mm. The count intensity in the correlation map varied depending on the incident position of the neutron beam which gives an evidence for the position-sensitivity of the detector. These experimental results were qualitatively understood by a simple solid-angle model.
Nakamura, Tatsuya; Katagiri, Masaki; Soyama, Kazuhiko; Ukibe, Masahiro*; Ikeuchi, Takashi*; Okubo, Masataka*
Nuclear Instruments and Methods in Physics Research A, 529(1-3), p.402 - 404, 2004/08
Times Cited Count:8 Percentile:48.76(Instruments & Instrumentation)We evaluated the neutron--rays discrimination of the neutron detector comprising a superconducting tunnel junction (STJ) on the single crystal of LiBO. The neutron detector was irradiated with X-rays, -rays and neutrons, and the signal pulses were analyzed including pulse height distributions and rise times. It was found that the most of the signal pulses for the neutron-events exhibited slower rise times than those for X-rays and -rays. This indicated the capability of neutron--rays discrimination of the detector using the differences in the decay time of the signal current.